Digital Free Beam SWIR Laser Vibrometer: Detect distant vibrations up to 300 m with our precision-enhancing Extra-Large-Lens system!
The Optomet Nova-Xtra is an extension of the Nova series and enables vibration measurements on distant objects with an extra-long range up to 300 m.
Higher laser power
Enhanced by the powerful yet discreet SWIR laser, the Nova-Xtra guarantees exceptional signal strength, ensuring optimal performance even in challenging conditions. This remarkable feature makes it the ultimate tool for professionals in civil engineering and the aerospace industry, who demand accuracy and reliability in their measurements.
Photodetectors in this wavelength range have an efficiency of more than 98%. In conjunction with the higher laser power, the signal level is 20 dB higher than that of conventional laser Doppler vibrometers.
Stability
With just a single longitudinal laser mode, the sensitivity is independent of changes in the measuring distance. The immediate operational readiness of the device after switching on and stability against fluctuations in the ambient temperature are further advantageous properties.
For added convenience and versatility, the Nova-Xtra offers an optional IR camera. This additional feature allows you to visualize and precisely locate the laser spot on the object of interest, further enhancing your workflow and facilitating precise measurements.
• Infrared laser (SWIR) for optimum signal quality
• Structural health monitoring by means of non-contact laser vibration measurement
• Compact all-in-one design ideal for mobile applications
• Best signal quality on all kinds of surfaces
• Simple and quick set-up
• Specially designed extra-long-range lens
• Reliable even under challenging conditions
• Update- and upgradeable firmware
• Optional infrared camera to locate the laser spot
Vibrational measurement of a bridge
Bridges, pipelines, other structures and industrial plants • High Buildings
Dark / rough surfaces • Moving or rotating objects, e.g., wind turbines
Restricted and inaccessible areas • Measurement on any material, e.g., concrete, metal
OptoGUI is an extensive and intuitive software for remote control, data acquisition, and data analysis when working in single-point mode. Data transfer is realized via a loss-free digital Gigabit Ethernet connection.
A detailed list of all vibrometer characteristics, including all hardware and software features, can be found in the vibrometer data sheet in Support & Datasheets.
Category | Characteristics |
---|---|
Laser source | SWIR-Laser |
Laser wavelength | Measurement laser: 1550 nm |
Targeting laser: 510-530 nm | |
Laser class | Measurement laser: output power: <10 mW, class 1 |
Targeting laser: output power: <1 mW, class 2 | |
Measured quantity | Velocity, Displacement, Acceleration |
Frequency bandwidths | DC to 25 MHz |
Max. vibrational velocity | 25 m/s |
Output signal (digital) | GBit-Ethernet (RJ45) / WiFi |
Output signal (analogue) | 3 x Standard BNC connectors |
Signal processing | Digital (Optomet UltraDSP) |
User interface output | Color screen 3.5" + 20 segment LED bargraph |
User interface input | Touch screen, knobs with push-button, key switch (power) |
Dimensions | Length x width x height (excluding handle and lens): 380 x 180 x 148 mm |
Weight | 8 kg |
Mounting | Standard tripod screw thread |
Power supply | 110 -240V AC (50-60Hz) oder 12V DC |
Power consumption | 27 Watt |
Operating temperature range | 0°C to 40°C |
A wide variety of high-performance real-time decoders are available for the evaluation of the interferometric measuring signals. The Optomet UltraDSP technology enables the measurement of frequencies up to 25 MHz and vibrational velocities up to 25 m/s with the Fiber-Series, displacements can be resolved to less than 100 fm. All vibrometers incorporate a velocity decoder, and displacement and acceleration decoders are optionally available. Numerous measuring ranges per decoder ensure that measurements can always be performed with the optimum sensitivity.
Decoders can be easily retrofitted or upgraded. Start with a basic system and adapt the capabilities of the measuring instrument as required. This requires no return of the instrument to the factory and no waiting times for your production or research project. The table below provides an overview of the configuration options. We will also be happy to assist you in the selection of the best decoder for your measuring task.
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-0N | 7 | 2.5 m/s | DC - 100 kHz | required |
Displacement Decoder D-DD-0N | 19 |
| optional | |
Acceleration Decoder D-AD-0N | 7 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-1N | 8 | 5 m/s | DC - 500 kHz | required |
Displacement Decoder D-DD-1N | 19 |
| optional | |
Acceleration Decoder D-AD-1N | 8 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-2N | 11 | 5 m/s | DC - 1 MHz | required |
Displacement Decoder D-DD-2N | 19 |
| optional | |
Acceleration Decoder D-AD-2N | 11 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-2N-R | 11 | 5 m/s | DC - 25 kHz | required |
Displacement Decoder D-DD-2N-R | 19 |
| optional | |
Acceleration Decoder D-AD-2N-R | 11 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-2N-12 | 12 | 12 m/s | DC - 1 MHz | required |
Displacement Decoder D-DD-2N-12 | 19 | optional | ||
Acceleration Decoder D-AD-2N-12 | 12 | optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-3N-12 | 9 | 12 m/s | DC - 2,5 MHz | required |
Displacement Decoder D-DD-3N-12 | 12 | optional | ||
Acceleration Decoder D-AD-3N-12 | 9 | optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-3N | 11 | 25 m/s | DC - 2,5 MHz | required |
Displacement Decoder D-DD-3N | 19 |
| optional | |
Acceleration Decoder D-AD-3N | 11 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-3N-30 | 12 | 30 m/s | DC - 2,5 MHz | required |
Displacement Decoder D-DD-3N-30 | 19 |
| optional | |
Acceleration Decoder D-AD-3N-30 | 12 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-4N | 9 | 12 m/s | DC - 10 MHz | required |
Displacement Decoder D-DD-4N | 19 |
| optional | |
Acceleration Decoder D-AD-4N | 11 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-5N | 14 | 25 m/s | DC- 10 MHz | required |
Displacement Decoder D-DD-5N | 19 |
| optional | |
Acceleration Decoder D-AD-5N | 14 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-5N-25 | 14 | 25 m/s | DC- 25 MHz | required |
Displacement Decoder D-DD-5N-25 | 19 |
| optional | |
Acceleration Decoder D-AD-5N-25 | 14 |
| optional |
Decoder Name | Number of measuring ranges | Max. vibrational velocity | Frequency | Comments |
---|---|---|---|---|
Velocity Decoder D-VD-5N-30 | 15 | 30 m/s | DC- 25 MHz | required |
Displacement Decoder D-DD-5N-30 | 19 |
| optional | |
Acceleration Decoder D-AD-5N-30 | 15 |
| optional |
Several lenses are available which are optimized for the Nova-Series. Choose the right optical system based on working distance, reflectivity of the surface to be measured or size of the focus point. The lenses are easily exchangeable due to a bayonet lock as on single-lens reflex cameras.
The table below provides an overview of the configuration options. We will also be happy to assist you in the selection of the best lens for your measuring task.
Extra-Long-Range lens
• Working distance: 2490 mm ... 300 m
• Autofocus, remote focus, manual focus
• Focus spot size (typ.): 170 µm at 2490 mm
Single Point Vibrometer Transport Case
Stable and waterproof Peli case for safe keeping and transport of vibrometer.
External dimension (L x B x H): 61.9 x 49.2 x 22.3 cm
Transport Bag
Compact und light transport bag for the outdoors-measurements
Telescope
For measurements from a greater distance, a telescope makes it easier to find the measuring point. The telescope can be easily mounted on the gauge rail at the top of the vibrometer.
IR-Camera
For digital visualizing of the laser point. The camera can be easily mounted on the gauge rail at the top of the vibrometer.
Tripod with Fluid Head
Precisely align your vibrometer with high quality tripods by Manfrotto.
Mobile Battery
Portable battery charger, external battery power bank. For powering the vibrometer when performing outdoor measurements.
IR-Detector Card
Transforming the not-visible infrared light into a spot of visible light.